AEL.TF.15 INTRODUCTORY AND OPERATING MANUAL THREE-PHASE ACTIVE ELECTRONIC ELECTRICITY METERS TS EN ISO

Pages 12
Views 12

Please download to get full document.

View again

of 12
All materials on our website are shared by users. If you have any questions about copyright issues, please report us to resolve them. We are always happy to assist you.
Description
AEL.TF.15 INTRODUCTORY AND OPERATING MANUAL THREE-PHASE ACTIVE ELECTRONIC ELECTRICITY METERS 0120 TS EN ISO 9001 CONTENTS Part Name Page No 0. Introduction 1 1. Introduction Technical Specifications of
Transcript
AEL.TF.15 INTRODUCTORY AND OPERATING MANUAL THREE-PHASE ACTIVE ELECTRONIC ELECTRICITY METERS 0120 TS EN ISO 9001 CONTENTS Part Name Page No 0. Introduction 1 1. Introduction Technical Specifications of the Electricity Meter 2 2. Main Functions 3 3. Structure And Operation Principle Of The Electricity Meter 4 4. Starting-Up The Electricity Meter 4 5. LCD Monitor Indicators 5 6. Connection Diagram 8 7. Diagram for assemblage measurement And Seal Points 8 8. EC Declaration Of Conformity 9 0. INTRODUCTION This manual describes the technical specifications of electronic electricity gauges measuring active electric energy and maximum energy absorbed, showing these data on LCD screen, automatically performing summer-winter hour applications, keeping desired information and programs in its memory, accessing these information when desired, which have been manufactured with advanced technology, and which comply with the specifications issued by Turkish Electricity Distribution Company (TEDAŞ) in order to promote electricity saving and to regulate multi-tariff electricity selling, and which comply with Regulation 2004/22/EC on Measurement Devices covered under the new approach statutes issued by EU. KÖHLER A.Ş. WARNING! BEFORE ASSEMBLY OF THE ELECTRICITY METER READ THIS MANUAL CAREFULLY. The electricity meter should be mounted only by licensed qualified personnel. During mounting, avoid contact with the parts with voltage. During mounting and dismounting the electricity meter, the power should be cut off. KÖHLER Electronic electricity meters are high-tech products. Any and all technical data and documents are under intellectual property of the Company; they may neither be reproduced nor used by third parties. This booklet provides summarized information about the electricity meter. Prior to assembly, qualified personnel should check whether the electricity meter type to be mounted is or is not in compliance with the electric supply system and electrical installation. Otherwise, the mounted electricity meter may be damaged because of faulty selection and connection of electricity meter. Such electricity meters shall not be assessed under the guarantee. The data displayed on the LCD monitor of the electricity meter are determined by TEDAŞ. Meter parameter settings and maintenance can not be done by user. Meter setting and maintenance process are done by only TEDAS personnel. (1) 1. TECHNICAL SPECIFICATIONS OF THE ELECTRICITY METER Type AEL.TF.15 3 Phase 4 Wire, 4 Tariff, Demand Measuring, Direct Name Connected, Outdoor, Active Electronic Electric Meter Class B Reference Voltage (Un) 3x230/400 V Reference Frequency (Fn) 50 Hz ±%5 Starting Current (Ist) 40mA (0,04.Itr) Minimum Current (Imin) 0,5 A Transition Current (Itr) 1 A Reference Current (In) 10 A Maximum Current (Imax) 1000 A Operating Voltage Range From 0,8Un to 1,15Un Protection Class IP54 Relative Humidity Ratio %95 Operating Temperature -40 ºC, +70 ºC (3K7) Mechanical Environment M1 (2004/22/EC Directive) Electromagnetic Environment E2 (2004/22/EC Directive) User Environment For Non-Condensing Humidity Environment Power Consumption Voltage Circuit : 2W, 10 VA Current Circuit : 4 VA Power Factor From 0 to ±1 ESD Voltage Resistance Contact Discharge : 8 kv Air Discharge : 15 kv Pulse Voltage 6 kv Meter Constant 1000 imp/kwh LCD Display 6+3 Digit Communication Speed Baud (IEC ) Interface Unit Optical Port (IEC ) Battery Life of the System 10 year Real Time Clock Battery Life 10 year Shelf Life of the Electricity Meter 4 year Time Clock Accuracy 0,5 s/day (at room temperature) (IEC-EN 61038) Data Storage Capacity 1 year Related Standards TS EN , TS EN Percentage Error Limits at Reference Conditions Current Range Power Factor Percentage Error Limit (%) 0,5A I 1A 1 ± 1,5 1A I 80A 0,5 ind.1..cap 0,8 ± 1 Opğopğpğpğ (2) 2. MAIN FUNCTIONS Gauging: The electricity meter gauge the total active power in four different tariffs. Programming the Electricity Meter: Time slices and tariffs are programmable. For a whole day, 8 different time slices may be determined and each time slice may be selected and paired with one tariff out of four. Furthermore, the electricity meter has a feature capable to tariff individually the weekdays, Saturdays and Sundays. On the electricity meter, the date and time, tariff data may be adjusted by the authorized TEDAŞ personnel by opening the lid of electric terminal box. Reading the Electricity Meter: Invoicing data for 12 months, consumed total power amount, data about lid openings of electric terminal box, demand data for 6 months and initial opening date of upper lid can be read on optic port of the electricity meter. Auto Trouble-Shooting Feature: The electricity meter continuously controls its internal circuits and displays in the menu of its monitor the trouble types shown hereunder. 1 The Upper Lid is Open Warning 2 Battery of the System is Warning The Lid of Electric Terminal Box is Open Warning Battery of the Clock is Weak Warning Clock Error Electric Terminal Box Lid and Upper Lid Opening, Closing, Recording Features: When the upper lid is opened, the first opening date is stored. When the lid of electric terminal box is opened, the first opening date of each month and total of openings throughout the relevant month is stored. Lid opening dates and numbers of the most recent 12 months are stored in the memory. Communication: The data is transmitted to a portable computer (indexor) through an optical reader from optic port of the electricity meter. Signal Output: On the electricity meter, there is two LEDs so as to indicate the consumed active energy. Numbers of blinks of these LEDs shows lmp/kwh values of the electricity meter lmp/kwh : 1000 Blinks = 1 kwh Summer/Winter Day Light Saving Time: The electricity meter automatically switches to summer / winter day time light saving time. Displaying during Power Failure: When the power is cut, the data requested can be brought to the LCD monitor via the call-button on the electricity meter and reading can be taken from optic port. (3) Supporting Power Real Time Clock LCD Screen Memory EEPROM Optic Communication 3. STRUCTURE AND OPERATION PRINCIPLE OF THE ELECTRICITY METER 3.1. Structure of the Electricity Meter Casing and lids of the electricity meter are incompliance with IP54 Outdoor Standard and fully sealed. The electricity meter is made of high-grade nonflammable plastics (PVC). All electronic components are laid on a special PCB card; and these cards are mounted to the casing of the electricity meter. Following calibration of the electricity meter, the upper lid is screwed in the factory and sealed by Ministry of Industry and Commerce of Republic of Türkiye. The lid of electric terminal box is sealed by authorized TEDAŞ personnel following assembly of the electricity meter Block Diagram of Operation Line Input R ST N Power Stage Voltage Sampling Current Sampling Line Output R S T N Gauge Chip Test Output Micro-processor Button 4. STARTING-UP THE ELECTRICITY METER Normally the electricity meter as well as the LCD monitor operates, when the meter is mounted and powered on Controlling the Functions Once the electricity meter is mounted, its electrical connections should be checked whether they are proper or not. After the electricity meter mounted properly to its place, the screw on the lid of the electric terminal box should be tightened. 2 nd lock indicator blinking on the LCD monitor will disappear after the first reading. If not, then it means either the lid of the electric terminal box is not attached properly or its screw is not tightened well. (4) 4.2. Operation of the LCD Monitor Following initial operation of the electricity meter, the auto-display mod will activate. Each menu of the display will be displayed for 5 seconds and then automatically proceed to the next informative menu. When the button on the electricity meter is pushed down, the button menu mod will activate and the data on the monitor will be stay for 1 minute on the monitor. After 1 minute it return to the auto-display mod. 5. LCD MONITOR INDICATORS Definitions of the symbols and indicators on the LCD Monitor are as follows: 1 2 The Upper Lid is Open This symbol indicates that the upper lid is opened. If the indicator is blinking while the lid is close, then it is indicating that the lid is opened earlier. If the indicator is being displayed on the monitor continuously, then the upper lid is on open position. The Lid of Electric Terminal Box is Open : This symbol indicates that the lid of the electric terminal box is opened. If the indicator is blinking while the lid is close, then it is indicating that the lid is opened earlier. If the indicator is being displayed on the monitor continuously, then the lid is on open position. Symbol will disappear after the electricity meter is read. Clock Error: If the clock does not operate normal, this symbol will be displayed. Battery of the System: If the voltage of the battery of the system is low, this symbol will be displayed. Battery of the Clock: If the voltage of the battery of the clock is low, this symbol will be displayed. Tariff display: These symbols indicate the timely using active tariff period of the electricity meter. These symbol indicate currently reading active tariff on the monitor. These symbol indicate the active energy unit. L1, L2 and L3 symbols indicate existence of, respectively, R, S and T phases. Using by the three-phase electricity meters. (5) 5.1 Samples from Display List Data Menu Hour Menu Total Active Energy Active Energy on the T1 Tariff Active Energy on the T2 Tariff Active Energy on the T3 Tariff (6) Active Energy on the T4 Tariff Maximum Demand Within the Mount Demand Date Demand Hour Version of the Programm Test Display (7) 6. CONNECTION DIAGRAM Inner diameter of phase and neutral sleeve of AEL.TF.15 10(100)A three-phase electricity meters is 6,3mm. If this electricity meter will be connected to a line of 100 Ampere, the cross section of copper and conductive part of line cable should at least be 25mm². The connection diagram of AEL.TF.15 three-phase electricity meter is given below H A T N Y Ü K 7. DIAGRAM FOR ASSEMBLAGE MEASUREMENT AND SEAL POINTS (8) 8. EC DECLARATION OF CONFORMITY (9) KÖHLER ELEKTRİK SAYAÇLARI SAN. VE TİC. A.Ş. ADRESS VE PHONES HEADQUARTERS: Bankalar Yanıkkapı Tenha Sok. Uçarlar Han No:8 Karaköy İSTANBUL / TÜRKİYE Tel: (0212) (6 Hat) Fax: (0212) FACTORIY: Akçaburgaz Mah. 58. Sok. No:3 Esenyurt İSTANBUL / TÜRKİYE Tel: (0212) (Pbx) Fax: (0212) DISTRICT OFFICES AND ELECTRICITY METER REPAIR MAINTENANCE AND CALIBRATION STATIONS ANKARA Sanayi Cad. Kuruçeşme Sok. No: 3/3 Ulus / ANKARA Tel: (0312) Fax: (0312) ADANA Karasoku Mah. Kızılay Cad Sk. Yusuf Çelik İş Merkezi Kat: 2 No: 7/203 ADANA Tel: (0322) Fax: (0322) İZMİR 1202/2 Sok. No: 80/L Temsil Plaza Gıda Çarşısı Yenişehir / İZMİR Tel: (0232) Fax: (0232)
We Need Your Support
Thank you for visiting our website and your interest in our free products and services. We are nonprofit website to share and download documents. To the running of this website, we need your help to support us.

Thanks to everyone for your continued support.

No, Thanks
SAVE OUR EARTH

We need your sign to support Project to invent "SMART AND CONTROLLABLE REFLECTIVE BALLOONS" to cover the Sun and Save Our Earth.

More details...

Sign Now!

We are very appreciated for your Prompt Action!

x