The following products presented in this data sheet are being withdrawn.

Pages 11
Views 4

Please download to get full document.

View again

of 11
All materials on our website are shared by users. If you have any questions about copyright issues, please report us to resolve them. We are always happy to assist you.
Description
EMC Filters Series/Type: 84 The following products presented in this data sheet are being withdrawn. Ordering Code Substitute Product Date of Withdrawal Deadline ast Orders ast Shipments 84000P
Transcript
EMC Filters Series/Type: 84 The following products presented in this data sheet are being withdrawn. Ordering Code Substitute Product Date of Withdrawal Deadline ast Orders ast Shipments 84000P EPCOS G 5. Reproduction, publication and dissemination of this publication, enclosures hereto and the information contained therein without EPCOS' prior express consent is prohibited. EPCOS G is a TD Group Company. Ordering Code Substitute Product Date of Withdrawal Deadline ast Orders ast Shipments For further information please contact your nearest EPCOS sales office, which will also support you in selecting a suitable substitute. The addresses of our worldwide sales network are presented at SIFI- for enhanced insertion loss 84 Power line filters for -phase systems Rated voltage V DC/C, /60 Hz Rated current to lternative version Series 84G (SIFI-G) offers a low-cost solution Construction -line filters Metal case Polyurethane potting (U 94 V-0) Features Compact design Optimized leakage current Cost-optimized construction lso for assembly on top-hat rails ENEC0, U and CS approval pplications Switch-mode power supplies in industrial electronics telecommunications data systems medical equipment DC applications Case styles and terminal styles Case style Case style Case style Case style Case style P Tab connectors on face ends, lateral fixing lugs. Particularly suitable for mounting on a shielding wall. Tab connectors on face ends, fixing lugs on face ends. IEC connector as per IEC 60 C 4 on line side, tab connectors on load side, mounting holes with metric thread. itz wires on face ends, fixing lugs on face ends Pins fitting PC standard grid Marking Marking on component: Manufacturer s logo, ordering code, rated voltage, rated current, rated temperature, climatic category, date code Minimum marking on packaging: Manufacturer s logo, ordering code Important notes at the end of this document. 0/06 SIFI- for enhanced insertion loss 84 Circuit diagram INE OD N N SS055-W Technical data and measuring conditions Rated voltage V R Rated current I R Test voltage V test eakage current l leak Climatic category (IEC ) pprovals V DC/C, /60 Hz Referred to 40 C ambient temperature 44 V DC, s (line/line) 0 V DC, s (lines/case) t 0 V C, Hz 5/085/ ( 5 C/85 C/ days damp heat test) EN 0, U 8, CS C. No.8 Important notes at the end of this document. 0/06 SIFI- for enhanced insertion loss 84 Characteristics and ordering codes I R C R R mh V R = V DC/C, /60 Hz 0.5 µf (X) 40 pf (Y) 0.5 µf (X) 40 pf (Y) 0. µf (X) 40 pf (Y) 6 0. µf (X) 40 pf (Y) µf (X) 40 pf (Y) 0.68 µf (X) 40 pf (Y) I leak m Case style 0.5 0.5 0.5 P 0.5 0.5 0.5 pprox. weight g Ordering code P Mounting plate for top-hat rail (ordering code) C609 C609 C609 C609 C609 C609 Important notes at the end of this document. 4 0/06 SIFI- for enhanced insertion loss 84 Case styles and dimensions Case style P I R Dimensions (mm) b b b b 4 l l l l 4 h h itz mm See dimensional drawing 79.5 See dimensional drawing Style 05 WG8 WG8 WG8 WG8 WG6 Important notes at the end of this document. 5 0/06 SIFI- for enhanced insertion loss 84 Case style Case style 0 ( ) (84000) b 84 b.5 4 h h 8 8. Tab connector 6. x Tab connector 6. x 4. ø b b 4 SS057-D-E SS05-I-E Case style Case style 0 ( ) (84000) b b 84.5 h h Tab connector 6. x ø Tab connector 6. x SS058--E ø4.7 SS054-R-E Important notes at the end of this document. 6 0/06 SIFI- for enhanced insertion loss 84 Case style Case style b 0± M h Tab connector 6. x Panel cutout ø ±0..5 6±.4± 6 _ N U 4± b ø4.7 N 6 _ GNYE U h SS055-Z-E SS059-U-E Case style P 8.0. ± 7.9±0. 5±0. 4.5±0.5 0.±0. 0±0..5± Output Ground Input ø.0. SS056-8-E Important notes at the end of this document. 7 0/06 SIFI- for enhanced insertion loss 84 Insertion loss (typical values at Z = Ω) unsymmetrical, adjacent branches terminated common mode, all branches in parallel (asymmetrical) differential mode (symmetrical) Filters for and Filters for α 00 d 84000* *0 SS049-Q 00 d α *00 SS0-T Hz Hz 0 8 f f Filters for 6 and 0 Filters for α 00 d 84000* *0 SS05-00 d α * SS Hz Hz 0 8 f f Important notes at the end of this document. 8 0/06 EMC filters Cautions and warnings Important information Please read all safety and warning notes carefully before installing the EMC filter and putting it into operation (see ). The same applies to the warning signs on the filter. Please ensure that the signs are not removed nor their legibility impaired by external influences. Death, serious bodily injury and substantial material damage to equipment may occur if the appropriate safety measures are not carried out or the warnings in the text are not observed. Using according to the terms The EMC filters may be used only for their intended application within the specified values in lowvoltage networks in compliance with the instructions given in the data sheets and the data book. The conditions at the place of application must comply with all specifications for the filter used. Warnings It shall be ensured that only qualified persons (electricity specialists) are engaged on work such as planning, assembly, installation, operation, repair and maintenance. They must be provided with the corresponding documentation. Danger of electric shock. EMC filters contain components that store an electric charge. Dangerous voltages can continue to exist at the filter terminals for longer than five minutes even after the power has been switched off. The protective earth connections shall be the first to be made when the EMC filter is installed and the last to be disconnected. Depending on the magnitude of the leakage currents, the particular specifications for making the protective-earth connection must be observed. Impermissible overloading of the EMC filter, such as impermissible voltages at higher frequencies that may cause resonances etc. can lead to destruction of the filter housing. EMC filters must be protected in the application against impermissible exceeding of the rated currents by suitable overcurrent protective. 9 0/06 EMC filters Important notes The following applies to all products named in this publication:. Some parts of this publication contain statements about the suitability of our products for certain areas of application. These statements are based on our knowledge of typical requirements that are often placed on our products in the areas of application concerned. We nevertheless expressly point out that such statements cannot be regarded as binding statements about the suitability of our products for a particular customer application. s a rule, EPCOS is either unfamiliar with individual customer applications or less familiar with them than the customers themselves. For these reasons, it is always ultimately incumbent on the customer to check and decide whether an EPCOS product with the properties described in the product specification is suitable for use in a particular customer application.. We also point out that in individual cases, a malfunction of passive electronic components or failure before the end of their usual service life cannot be completely ruled out in the current state of the art, even if they are operated as specified. In customer applications requiring a very high level of operational safety and especially in customer applications in which the malfunction or failure of a passive electronic component could endanger human life or health (e.g. in accident prevention or life-saving systems), it must therefore be ensured by means of suitable design of the customer application or other action taken by the customer (e.g. installation of protective circuitry or redundancy) that no injury or damage is sustained by third parties in the event of malfunction or failure of a passive electronic component.. The warnings, cautions and product-specific notes must be observed. 4. In order to satisfy certain technical requirements, some of the products described in this publication may contain substances subject to restrictions in certain jurisdictions (e.g. because they are classed as hazardous ). Useful information on this will be found in our Material Data Sheets on the Internet (www.epcos.com/material). Should you have any more detailed questions, please contact our sales offices. 5. We constantly strive to improve our products. Consequently, the products described in this publication may change from time to time. The same is true of the corresponding product specifications. Please check therefore to what extent product descriptions and specifications contained in this publication are still applicable before or when you place an order. We also reserve the right to discontinue production and delivery of products. Consequently, we cannot guarantee that all products named in this publication will always be available. 6. Unless otherwise agreed in individual contracts, all orders are subject to the current version of the General Terms of Delivery for Products and Services in the Electrical Industry published by the German Electrical and Electronics Industry ssociation (ZVEI). 7. The trade names EPCOS, EPCOS-Jones, aoke, CeraDiode, CSSP, MSC, PhaseCap, PhaseMod, SIFI, SIORE, SilverCap, SIMID, SIOV, SIP5D, SIP5, UltraCap, WindCap are trademarks registered or pending in Europe and in other countries. Further information will be found on the Internet at 0 0/06
Advertisements
Related Documents
View more...
We Need Your Support
Thank you for visiting our website and your interest in our free products and services. We are nonprofit website to share and download documents. To the running of this website, we need your help to support us.

Thanks to everyone for your continued support.

No, Thanks
SAVE OUR EARTH

We need your sign to support Project to invent "SMART AND CONTROLLABLE REFLECTIVE BALLOONS" to cover the Sun and Save Our Earth.

More details...

Sign Now!

We are very appreciated for your Prompt Action!

x